STP8-17TL-IA-en-31 | IMEN-STP10-17TL | Version 3.1ENPV InverterSUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TLInstallation Manual
2 Safety SMA Solar Technology AG10 STP8-17TL-IA-en-31 Installation ManualWhen designing the PV plant, ensure that the permitted operating range of al
14 Technical Data SMA Solar Technology AG100 STP8-17TL-IA-en-31 Installation ManualEarthing systemsData Storage CapacityEfficiencyTN-C network suitab
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 10114.2 Sunny Tripower 10000TLDC Input* The maximum open-circuit volt
14 Technical Data SMA Solar Technology AG102 STP8-17TL-IA-en-31 Installation ManualAC Output* Depending on country settingRated power at 230 V, 50 Hz
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 103Protective DevicesGeneral DataDC reverse polarity protection Short
14 Technical Data SMA Solar Technology AG104 STP8-17TL-IA-en-31 Installation Manual* VDE-AR-N-4105: valid from Firmware Version 2.31. Setting in acco
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 105FeaturesElectronic Solar SwitchTorquesDC connection SUNCLIX DC con
14 Technical Data SMA Solar Technology AG106 STP8-17TL-IA-en-31 Installation ManualEarthing systemsData Storage CapacityEfficiencyTN-C network suitab
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 10714.3 Sunny Tripower 12000TLDC Input* The maximum open-circuit volt
14 Technical Data SMA Solar Technology AG108 STP8-17TL-IA-en-31 Installation ManualAC Output* Depending on country settingRated power at 230 V, 50 Hz
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 109Protective DevicesGeneral DataDC reverse polarity protection Short
SMA Solar Technology AG 2 SafetyInstallation Manual STP8-17TL-IA-en-31 112.3 Explanation of SymbolsThis section gives an explanation of all the symb
14 Technical Data SMA Solar Technology AG110 STP8-17TL-IA-en-31 Installation Manual* VDE-AR-N-4105: valid from Firmware Version 2.31. Setting in acco
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 111FeaturesElectronic Solar SwitchTorquesDC connection SUNCLIX DC con
14 Technical Data SMA Solar Technology AG112 STP8-17TL-IA-en-31 Installation ManualEarthing SystemsData Storage CapacityEfficiencyTN-C network suitab
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 11314.4 Sunny Tripower 15000TLDC Input* The maximum open-circuit volt
14 Technical Data SMA Solar Technology AG114 STP8-17TL-IA-en-31 Installation ManualAC Output* Depending on country settingRated power at 230 V, 50 Hz
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 115Protective DevicesGeneral DataDC reverse polarity protection Short
14 Technical Data SMA Solar Technology AG116 STP8-17TL-IA-en-31 Installation Manual* VDE-AR-N-4105: valid from Firmware Version 2.31. Setting in acco
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 117FeaturesElectronic Solar SwitchTorquesDC connection SUNCLIX DC con
14 Technical Data SMA Solar Technology AG118 STP8-17TL-IA-en-31 Installation ManualEarthing SystemsData Storage CapacityEfficiencyTN-C network suitab
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 11914.5 Sunny Tripower 17000TLDC Input* The maximum open-circuit volt
2 Safety SMA Solar Technology AG12 STP8-17TL-IA-en-31 Installation Manual2.3.2 Symbols on the Type LabelSymbol Description ExplanationDanger to life
14 Technical Data SMA Solar Technology AG120 STP8-17TL-IA-en-31 Installation ManualAC Output* Depending on country settingRated power at 230 V, 50 Hz
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 121Protective DevicesGeneral DataDC reverse polarity protection Short
14 Technical Data SMA Solar Technology AG122 STP8-17TL-IA-en-31 Installation Manual* VDE-AR-N-4105: valid from Firmware Version 2.31. Setting in acco
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 123FeaturesElectronic Solar SwitchTorquesDC connection SUNCLIX DC con
14 Technical Data SMA Solar Technology AG124 STP8-17TL-IA-en-31 Installation ManualEarthing SystemsData Storage CapacityEfficiencyTN-C network suitab
SMA Solar Technology AG 15 AccessoriesInstallation Manual STP8-17TL-IA-en-31 12515 AccessoriesYou will find the corresponding accessories and spare p
16 Contact SMA Solar Technology AG126 STP8-17TL-IA-en-31 Installation Manual16 ContactIf you have technical problems concerning our products, contact
SMA Solar Technology AG Legal ProvisionsInstallation Manual STP8-17TL-IA-en-31 127Legal ProvisionsThe information contained in this document is the pr
www.SMA-Solar.comSMA Solar TechnologySMA Solar Technology AGwww.SMA.deSMA Australia Pty. Ltd.www.SMA-Australia.com.auSMA Benelux bvba/sprlwww.SMA-Bene
SMA Solar Technology AG 2 SafetyInstallation Manual STP8-17TL-IA-en-31 13RAL quality mark for solar productsThe product complies with the requirement
3 Product Description SMA Solar Technology AG14 STP8-17TL-IA-en-31 Installation Manual3 Product DescriptionThe Sunny Tripower is a multi-string inve
SMA Solar Technology AG 3 Product DescriptionInstallation Manual STP8-17TL-IA-en-31 153.3 Multi-Function InterfaceThe inverter is equipped with a sl
3 Product Description SMA Solar Technology AG16 STP8-17TL-IA-en-31 Installation Manual3.6 Intelligent String Failure DetectionThe Sunny Tripower is
SMA Solar Technology AG 3 Product DescriptionInstallation Manual STP8-17TL-IA-en-31 173.7 Electronic String FuseThe Sunny Tripower is equipped with
4 Unpacking SMA Solar Technology AG18 STP8-17TL-IA-en-31 Installation Manual4 Unpacking4.1 Scope of DeliveryCheck the delivery for completeness and
SMA Solar Technology AG 4 UnpackingInstallation Manual STP8-17TL-IA-en-31 194.2 Identifying the InverterYou can identify the inverter by the type la
5 Mounting SMA Solar Technology AG20 STP8-17TL-IA-en-31 Installation Manual5 Mounting5.1 SafetyDanger to life due to fire or explosionDespite caref
SMA Solar Technology AG 5 MountingInstallation Manual STP8-17TL-IA-en-31 215.2 Selecting the Mounting LocationTake the following requirements into c
5 Mounting SMA Solar Technology AG22 STP8-17TL-IA-en-31 Installation Manual• Observe the recommended clearances to walls, other inverters or other ob
SMA Solar Technology AG 5 MountingInstallation Manual STP8-17TL-IA-en-31 232. Mount the rear panel.To do this, use one upper hole on the right and on
5 Mounting SMA Solar Technology AG24 STP8-17TL-IA-en-31 Installation Manual3. Hook the inverter into the rear panel, ensuring that the inverter enclo
SMA Solar Technology AG 5 MountingInstallation Manual STP8-17TL-IA-en-31 257. Screw the supplied eye bolt into the hole provided in order to secure t
5 Mounting SMA Solar Technology AG26 STP8-17TL-IA-en-31 Installation ManualOptional Anti-Theft ProtectionTo protect the inverter from theft, you can
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 276 Electrical Connection6.1 Safety6.2 Overview of the Conne
6 Electrical Connection SMA Solar Technology AG28 STP8-17TL-IA-en-31 Installation ManualObject DescriptionA Electronic Solar Switch (ESS) socketB Cab
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 296.3 Connecting the Electricity Grid (AC)6.3.1 Conditions fo
SMA Solar Technology AG Table of ContentsInstallation Manual STP8-17TL-IA-en-31 3Table of Contents1 Information on this Manual. . . . . . . . . . . .
6 Electrical Connection SMA Solar Technology AG30 STP8-17TL-IA-en-31 Installation ManualConnection of a second protective conductorIn some installati
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 316.3.2 AC Connection Procedure1. Check the line voltage and c
6 Electrical Connection SMA Solar Technology AG32 STP8-17TL-IA-en-31 Installation ManualIf the inverter is not set to the desired country standard, a
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 3312. Screw the cap nut of the cable gland down tightly on the
6 Electrical Connection SMA Solar Technology AG34 STP8-17TL-IA-en-31 Installation Manual6.4 Connecting the PV Array (DC)6.4.1 Conditions for DC Con
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 35• The following thresholds at the DC input of the inverter mu
6 Electrical Connection SMA Solar Technology AG36 STP8-17TL-IA-en-31 Installation ManualFunction of the electronic string fuseThe electronic string f
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 376.4.2 Assembling the DC ConnectorsFor connection to the inve
6 Electrical Connection SMA Solar Technology AG38 STP8-17TL-IA-en-31 Installation Manual4. Push the swivel nut up to the thread and tighten (torque:
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 396.4.3 Opening the DC Connector1. Unscrew the swivel nut.2. T
Table of Contents SMA Solar Technology AG4 STP8-17TL-IA-en-31 Installation Manual6 Electrical Connection . . . . . . . . . . . . . . . . . . . . . .
6 Electrical Connection SMA Solar Technology AG40 STP8-17TL-IA-en-31 Installation Manual6.4.4 Connecting the PV Array (DC)Danger to life due to high
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 411. Check the connection cables of the PV modules for correct
6 Electrical Connection SMA Solar Technology AG42 STP8-17TL-IA-en-31 Installation Manual4. If more than 2 strings are to be connected, check the firs
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 436. Follow the same procedure to connect all further strings.I
6 Electrical Connection SMA Solar Technology AG44 STP8-17TL-IA-en-31 Installation Manual8. In order to seal the inverter, all DC inputs that are not
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 456.5 Setting the Country Standard and Display LanguageThe inv
6 Electrical Connection SMA Solar Technology AG46 STP8-17TL-IA-en-31 Installation ManualIt is also possible to configure country data sets (parameter
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 476.5.1 Checking the Country StandardCheck whether the inverte
6 Electrical Connection SMA Solar Technology AG48 STP8-17TL-IA-en-31 Installation Manual0 7 retained not assigned* dependent on parameter setdependen
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 497 6 PPDS German yes Czech Republic7 8 C10/11 French yes Belgi
SMA Solar Technology AG Table of ContentsInstallation Manual STP8-17TL-IA-en-31 510 Maintenance and Cleaning . . . . . . . . . . . . . . . . . . . .
6 Electrical Connection SMA Solar Technology AG50 STP8-17TL-IA-en-31 Installation ManualIf the inverter is not set to the country of installation, th
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 516.5.2 Extension of the Deactivation LimitsThe deactivation c
6 Electrical Connection SMA Solar Technology AG52 STP8-17TL-IA-en-31 Installation Manual6.5.3 Setting the Country Standard and Language using the Ro
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 536.6 Communication6.6.1 BluetoothCommunication via Bluetooth
6 Electrical Connection SMA Solar Technology AG54 STP8-17TL-IA-en-31 Installation ManualTo do this, proceed as follows:1. Disconnect the inverter (se
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 556.7 Retrofitting a Surge Arrester Type IIThe inverter can be
6 Electrical Connection SMA Solar Technology AG56 STP8-17TL-IA-en-31 Installation Manual– The surge arrester marked "PE 500" must be insert
SMA Solar Technology AG 6 Electrical ConnectionInstallation Manual STP8-17TL-IA-en-31 576. Pre-screw all 4 screws of the DC lid and then tighten them
7 Commissioning SMA Solar Technology AG58 STP8-17TL-IA-en-31 Installation Manual7 Commissioning7.1 Commissioning the Inverter1. Check that the devi
SMA Solar Technology AG 7 CommissioningInstallation Manual STP8-17TL-IA-en-31 599. Plug the Electronic Solar Switch in firmly right up to the stop. 1
Table of Contents SMA Solar Technology AG6 STP8-17TL-IA-en-31 Installation Manual15 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Commissioning SMA Solar Technology AG60 STP8-17TL-IA-en-31 Installation Manual7.2 Display Messages during the Start Phase• The firmware version of
SMA Solar Technology AG 8 ConfigurationInstallation Manual STP8-17TL-IA-en-31 618 Configuration8.1 Changing the Plant Time and Plant PasswordRequir
8 Configuration SMA Solar Technology AG62 STP8-17TL-IA-en-31 Installation Manual8.3 Activating the Intelligent String Failure DetectionThe intellige
SMA Solar Technology AG 9 Disconnecting the Inverter from Voltage SourcesInstallation Manual STP8-17TL-IA-en-31 639 Disconnecting the Inverter from
9 Disconnecting the Inverter from Voltage Sources SMA Solar Technology AG64 STP8-17TL-IA-en-31 Installation Manual9.2 Procedure1. Disconnect the min
SMA Solar Technology AG 9 Disconnecting the Inverter from Voltage SourcesInstallation Manual STP8-17TL-IA-en-31 657. Use a suitable multimeter to ver
9 Disconnecting the Inverter from Voltage Sources SMA Solar Technology AG66 STP8-17TL-IA-en-31 Installation Manual10. Release and disconnect all DC c
SMA Solar Technology AG 10 Maintenance and CleaningInstallation Manual STP8-17TL-IA-en-31 6710 Maintenance and Cleaning10.1 Cleaning the Inverter10.2
10 Maintenance and Cleaning SMA Solar Technology AG68 STP8-17TL-IA-en-31 Installation Manual10.2.1 Cleaning the Ventilation GridsThe inverter takes c
SMA Solar Technology AG 10 Maintenance and CleaningInstallation Manual STP8-17TL-IA-en-31 6910.2.2 Cleaning the Fan at the Bottom of the Inverter (S
SMA Solar Technology AG 1 Information on this ManualInstallation Manual STP8-17TL-IA-en-31 71 Information on this Manual1.1 ValidityThis manual des
10 Maintenance and Cleaning SMA Solar Technology AG70 STP8-17TL-IA-en-31 Installation Manual9. After cleaning, reassemble everything in reverse order
SMA Solar Technology AG 10 Maintenance and CleaningInstallation Manual STP8-17TL-IA-en-31 717. Release and remove the plug.The fan cables are long en
10 Maintenance and Cleaning SMA Solar Technology AG72 STP8-17TL-IA-en-31 Installation Manual10.3 Checking the Electronic Solar Switch (ESS) for WearC
SMA Solar Technology AG 11 MessagesInstallation Manual STP8-17TL-IA-en-31 7311 Messages11.1 Event MessagesDuring an update, the relevant display mess
11 Messages SMA Solar Technology AG74 STP8-17TL-IA-en-31 Installation Manual11.2 Error messagesThe text line on the display shows the relevant displa
SMA Solar Technology AG 11 MessagesInstallation Manual STP8-17TL-IA-en-31 75301 < Grid fault >The 10-minute-average line voltage is no longer w
11 Messages SMA Solar Technology AG76 STP8-17TL-IA-en-31 Installation Manual701 < Frq. not permitted > < Check parameter > The power fre
SMA Solar Technology AG 11 MessagesInstallation Manual STP8-17TL-IA-en-31 773301 … 3303< Unstable operation >There is not enough power at the D
11 Messages SMA Solar Technology AG78 STP8-17TL-IA-en-31 Installation Manual3801, 3802< DC overcurrent > < Check generator >On the DC si
SMA Solar Technology AG 11 MessagesInstallation Manual STP8-17TL-IA-en-31 794003 < String X defect. > < Check generator >The "X"
1 Information on this Manual SMA Solar Technology AG8 STP8-17TL-IA-en-31 Installation Manual1.4 Symbols UsedThe following types of safety precaution
11 Messages SMA Solar Technology AG80 STP8-17TL-IA-en-31 Installation Manual6430 < Relay control defective input X >X stands for the affected i
SMA Solar Technology AG 11 MessagesInstallation Manual STP8-17TL-IA-en-31 817106 < Update file defect. > • Re-format the SD card.• Re-save the
11 Messages SMA Solar Technology AG82 STP8-17TL-IA-en-31 Installation Manual7508 < Fan fault > < Clean fan >One of the external fans is
SMA Solar Technology AG 11 MessagesInstallation Manual STP8-17TL-IA-en-31 839003 < Grid param. locked >The current country data set is locked.•
12 Troubleshooting SMA Solar Technology AG84 STP8-17TL-IA-en-31 Installation Manual12 Troubleshooting12.1 Sunny Tripower is BeepingElectric shock due
SMA Solar Technology AG 12 TroubleshootingInstallation Manual STP8-17TL-IA-en-31 8512.2 Checking the PV Array for Earth FaultsIf the inverter display
12 Troubleshooting SMA Solar Technology AG86 STP8-17TL-IA-en-31 Installation Manual☑ An earth fault is present if the measured voltages are stable an
SMA Solar Technology AG 12 TroubleshootingInstallation Manual STP8-17TL-IA-en-31 8712.3 Checking the Function of the VaristorsIf the inverter display
12 Troubleshooting SMA Solar Technology AG88 STP8-17TL-IA-en-31 Installation Manual4. Remove all varistors by pulling them upwards.If you have not re
SMA Solar Technology AG 12 TroubleshootingInstallation Manual STP8-17TL-IA-en-31 896. Insert an insertion tool into the openings of the terminal cont
SMA Solar Technology AG 2 SafetyInstallation Manual STP8-17TL-IA-en-31 92 Safety2.1 Intended UseThe Sunny Tripower is a PV inverter which converts
12 Troubleshooting SMA Solar Technology AG90 STP8-17TL-IA-en-31 Installation Manual12.4 Replacing Surge Arresters Type IIIf the inverter is displayin
SMA Solar Technology AG 12 TroubleshootingInstallation Manual STP8-17TL-IA-en-31 914. Remove all surge arresters from the slots. To do this, compress
13 Decommissioning SMA Solar Technology AG92 STP8-17TL-IA-en-31 Installation Manual13 Decommissioning13.1 Dismantling the Inverter1. Disconnect the i
SMA Solar Technology AG 13 DecommissioningInstallation Manual STP8-17TL-IA-en-31 931. Dismantle the inverter (see Section13.1 "Dismantling the
13 Decommissioning SMA Solar Technology AG94 STP8-17TL-IA-en-31 Installation Manual13.3 Packing the Inverter• If the original packaging is available,
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 9514 Technical Data14.1 Sunny Tripower 8000TLDC Input* The maximum op
14 Technical Data SMA Solar Technology AG96 STP8-17TL-IA-en-31 Installation ManualAC Output* Depending on country settingRated power at 230 V, 50 Hz
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 97Protective DevicesGeneral DataDC reverse polarity protection Short-
14 Technical Data SMA Solar Technology AG98 STP8-17TL-IA-en-31 Installation Manual* VDE-AR-N-4105: valid from Firmware Version 2.31. Setting in accor
SMA Solar Technology AG 14 Technical DataInstallation Manual STP8-17TL-IA-en-31 99FeaturesElectronic Solar SwitchTorquesDC connection SUNCLIX DC conn